ZTD Cold Aisle Containment

Brand: YPVALUE

Series :YPVALUE SmartDC Series 
Application scenario: data center communication room office building weak current monitoring shopping center bank Airport
Suitable for 19 "network equipment, server equipment


Product advantages:
one   The closed cold channel system module of data center realizes green energy saving through closed cold channel, which is an effective way to solve the cooling problem of high heat density cabinet in data center. On the premise of the same refrigeration effect, compared with the traditional open cold and hot channel, the air supply volume of the indoor fan in the closed cold channel is 60% of the traditional open cold channel, which means that the power consumption in the closed cold channel is 60% of the traditional open cold channel, and the energy consumption can be saved by more than 40%.
two   Cold channel solution is in response to "energy saving and emission reduction in computer room, promoting green new computer room" came into being. It is mainly used for IDC data center computer room with large heat dissipation, playing the effect of accurate air supply. It consists of two columns of cabinet matrix. The traditional room air-conditioning can not be effectively controlled, cold (source) channeling, resulting in uneven heat and cold in the room, resulting in local hot spots. The cold channel cabinet delivers all the cold air to the cooling equipment in the most economical and effective way, and the heat in the cabinet is delivered out of the cabinet along the specified direction.


Structural advantages:
one   The top cover of the cold channel adopts flat top structure, which is 350mm higher than the top of the cabinet. The total width of the top cover is 1305mm. The modular grid standard design has strong interchangeability and easy installation.
two   The clear height of the cooling channel after the movable skylight is opened is more than 2m or above, which does not affect the daily maintenance work.
three   The cold channel is unit modular design, each unit can be installed independently, and can be connected with adjacent units, with strong interchangeability and flexible assembly. The horizontal connection between the frame and the horizontal bracket of the cabinet not only strengthens the channel itself, but also has the function of convenient expansion.
four   A pair of moving doors are respectively set between the head and tail of the train, which has good sealing effect and can effectively restrain the hot air flow into the equipment. The preset port of the cold channel is linked with the whole fire control system of the computer room, which can automatically open the movable skylight according to the fire signal (switch signal) and meet the fire demand in the channel.
five   All the unit components of the cold channel adopt unique good wear resistance and corrosion resistance, fine processing, integral stamping forming, high reliable contact, and the unit opening life test shall not be less than 5000 times, which is safe and durable without looseness, so as to ensure the air flow output sealing.
Quality standard: comply with eia-310-e, din41491; PART1,IEC297-2,DIN41494; Part7, GB / t3047.2-92 standard; Compatible with ETSI standard; Meet the requirements of Rosh and CE;

Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
1
Detail
右侧内容区域
Product Series:
SmartDC Series
Product type:
Data Center Cold & Hot Aisles

YPVALUE SmartDC Series ZTD Data Center Cold Aisle YPVALUE SmartDC Series ZTD Data Center Cold Aisle YPVALUE SmartDC Series ZTD Data Center Cold Aisle YPVALUE SmartDC Series ZTD Data Center Cold Aisle

 

Keyword:
cold aisle vs hot aisle
cold aisle isolation
cold aisle curtains
cold aisle containment wiki
We could not find any corresponding parameters, please add them to the properties table

Brand: YPVALUE

Series :YPVALUE SmartDC Series 
Application scenario: data center communication room office building weak current monitoring shopping center bank Airport
Suitable for 19 "network equipment, server equipment


Product advantages:
one   The closed cold channel system module of data center realizes green energy saving through closed cold channel, which is an effective way to solve the cooling problem of high heat density cabinet in data center. On the premise of the same refrigeration effect, compared with the traditional open cold and hot channel, the air supply volume of the indoor fan in the closed cold channel is 60% of the traditional open cold channel, which means that the power consumption in the closed cold channel is 60% of the traditional open cold channel, and the energy consumption can be saved by more than 40%.
two   Cold channel solution is in response to "energy saving and emission reduction in computer room, promoting green new computer room" came into being. It is mainly used for IDC data center computer room with large heat dissipation, playing the effect of accurate air supply. It consists of two columns of cabinet matrix. The traditional room air-conditioning can not be effectively controlled, cold (source) channeling, resulting in uneven heat and cold in the room, resulting in local hot spots. The cold channel cabinet delivers all the cold air to the cooling equipment in the most economical and effective way, and the heat in the cabinet is delivered out of the cabinet along the specified direction.


Structural advantages:
one   The top cover of the cold channel adopts flat top structure, which is 350mm higher than the top of the cabinet. The total width of the top cover is 1305mm. The modular grid standard design has strong interchangeability and easy installation.
two   The clear height of the cooling channel after the movable skylight is opened is more than 2m or above, which does not affect the daily maintenance work.
three   The cold channel is unit modular design, each unit can be installed independently, and can be connected with adjacent units, with strong interchangeability and flexible assembly. The horizontal connection between the frame and the horizontal bracket of the cabinet not only strengthens the channel itself, but also has the function of convenient expansion.
four   A pair of moving doors are respectively set between the head and tail of the train, which has good sealing effect and can effectively restrain the hot air flow into the equipment. The preset port of the cold channel is linked with the whole fire control system of the computer room, which can automatically open the movable skylight according to the fire signal (switch signal) and meet the fire demand in the channel.
five   All the unit components of the cold channel adopt unique good wear resistance and corrosion resistance, fine processing, integral stamping forming, high reliable contact, and the unit opening life test shall not be less than 5000 times, which is safe and durable without looseness, so as to ensure the air flow output sealing.
Quality standard: comply with eia-310-e, din41491; PART1,IEC297-2,DIN41494; Part7, GB / t3047.2-92 standard; Compatible with ETSI standard; Meet the requirements of Rosh and CE;

Related products

Message

Your valuable opinions are our driving force

Username used for comment:
客户留言
Description:
验证码
留言板

24-Hour Hour Hotline

+86-15888037338

生活赋能科技,科技改变生活

Life empowers technology, technology changes life

Top